Start / Drives modules & components / AC drives / Unidrive M400 - (0,25 kW-110 kW)

Features and application

Simple AC drive with extended safety function and built-in PLC CodeSys controller.Unidrive-M400 AC drive

  • Open loop V/Hz or vector control, open loop rotor flux control for induction motors (RFC-A)
  • Built-in RFI A class filter
  • Built-in PID controller
  • Built-in braking regulator
  • One module slot for additional I/O options (frame size 2 and upwards)
  • Speed and torque control
  • Unidrive M Connect free software tool for the control and monitoring via PC
  • Built-in double safety input Safe Torque Off
  • Possible PLC programming in CodeSys

Specification

  • Power supply (1x110 V, 1x230 V, 3x230 V, 3x400 V, 3x575 V, 3x690 V) ± 10%
  • Power 0.25 -110 kW
  • High overload capability – 150 % for 60 s
  • Output frequency 0-550 Hz
  • IP-20 protection degree housing

Options

  • SI-PROFIBUS – Module for PROFIBUS communication protocol
  • SI-DeviceNet – Module for DeviceNet communication protocol
  • SI-CANopen – Module for CANopen communication protocol
  • SI-Ethernet – External module of Ethernet communication module, supporting PROFINET RT, EtherNet/IP and Modbus TCP/IP
  • SI-EtherCAT – Module for EtherCAT communication protocol
  • SI-I/O – Extended I/O interface module increasing the number of I/O points on a drive. Additional characteristics: 4x digital I/O, 3 x analogue inputs (default) / digital inputs, 1 x analogue output (default) / digital input, 2 x relays
  • SI-Safety – Module offering an intelligent and programmable solution, ensuring compliance with the requirements of the IEC 61800-5-2 safety standard
  • AI-Back-up Adaptor – Adaptor allowing the drive to use an SD card for parameter cloning and acting as an input for 24 V back-up
  • AI-485 Adaptor – Adaptor for RS485 communications
  • CI-485 Adaptor – Adaptor for RS485 communications; commonly used for connection with a remote panel or RS485 communication in the absence or unavailability of AI-485 adaptor
  • Optional Remote Keypad
  • CT USB Comms – USB communication cable allowing the drive to connect to a PC for use with Unidrive M’s PC tools

Download

Software

Drive interface elements

Drive interface elements  
Al-Back-up adaptor (backup power supply)
Al-Smart adaptor (backup power supply)

Adaptor Al-485 (communication)
Adaotir CI-485 (communication)
Communication cable CT USB Comms 


Contact

Sales

Andrzej Gajtkowski

Module Sales Division Manager

+48 797 991 410

+48 56 654 49 06

andrzej.gajtkowski@apator.com

Technical

Krzysztof Wnuk-Lipiński

Support & Training Services Specialist

+48 506 094 170

+48 56 654 49 26

krzysztof.wnuk-lipinski@apator.com

This site uses cookies. By using this website you agree to the use of cookies in accordance with current browser settings. Using our website without changing the settings for cookies is that they will be stored in memory. More information can be found in our Privacy Policy.
You can change the settings for cookies.

zamknięcie cookie's