Start / Drives modules & components / Programmable Logic Controllers

CPU

All Programmable Logic Controllers are available in versions with relay outputs and transistor outputs. Powered with 24 VDC voltage. They allow to extend the device capability by adding additional modules (both right and left-hand).

 

CPU

DVP-SA2DVP-SA2:

  • Programmable Logic Controller for advanced applications
  • With 8 high-speed digital inputs and 4 high-speed digital outputs
  • Large memory 16 k steps for creating advanced programmes
  • Communication ports 1xRS232 and 1xRS485

DVP-SS2DVP-SS2:

  • Programmable Logic Controller for standard applications
  • With 8 digital inputs and 6 digital outputs
  • Memory of the controller: 8 k steps
  • With communication ports 1xRS232 and 1xRS485

DVP-SV2DVP-SV2:

  • Programmable Logic Controller for advanced applications
  • Provides support also for high-speed and high-precision motion applications
  • With 16 high-speed digital inputs and 12 high-speed digital outputs
  • Very large memory that saves up to 30 k steps
  • Communication ports 1xRS232 and 1xRS485

DVP-SX2DVP-SX2:

  • Programmable Logic Controller with built-in analogue inputs
  • With 8 digital inputs, 6 digital outputs, 4 analogue inputs, and 2 analogue outputs
  • Large memory 16 k steps
  • Communication ports 1xRS232 and 1xRS485

DVP-SEDVP-SE:

  • Programmable Logic Controller with Ethernet port
  • With 8 high-speed digital inputs and 4 high-speed digital outputs
  • Large memory 16 k steps for creating advanced programmes
  • Communication ports 1xRS232 and 1xRS485, 1xUSB and 1xEthernet

Analogue inputs/outputs (AI/AO)

Analogue inputs/outputs (AI/AO)

PLC DVP-04AD-SDVP-04AD-S:

  • With 4 analogue inputs (voltage/current)
  • 24VDC power supply
  • 14-bit converter for voltage signal
  • 13-bit converter for current signal
  • Voltage signal -10..+10V
  • Current signal -20..+20mA
  • Right-hand module

PLC DVP-04AD-SLDVP-04AD-SL:

  • With 4 high-speed analogue inputs (voltage/current)
  • 24VDC power supply
  • 16-bit converter
  • Voltage signal -10..+10 V
  • Current signal -20..+20 mA
  • Left-hand module

PLC DVP-02DA-SDVP-02DA-S:

  • With 2 analogue outputs (voltage/current)
  • 24VDC power supply
  • 12-bit converter for voltage and current signal
  • Voltage signal 0..10 V
  • Current signal 0..20 mA
  • Right-hand module

PLC DVP-04DA-SDVP-04DA-S:

  • With 4 analogue outputs (voltage/current)
  • 24VDC power supply
  • 12-bit converter for voltage and current signal
  • Voltage signal 0..10 V
  • Current signal 0..20 mA
  • Right-hand module

PLC DVP-04DA-SLDVP-04DA-SL:

  • With 4 high-speed analogue outputs (voltage/current)
  • 24VDC power supply
  • 16-bit converter
  • Voltage signal -10..10 V
  • Current signal 0..20 mA
  • Left-hand module

PLC DVP-06XA-SDVP-06XA-S:

  • With 4 analogue inputs and 2 analogue outputs (voltage/current)
  • 24 VDC power supply
  • 12-bit converter
  • Voltage signal for inputs -10..+10 V, for outputs 0..10 V
  • Current signal for inputs -20 mA..+20 mA, for outputs 0..20 mA
  • Right-hand module

PLC DVP-04PT-SDVP-04PT-S:

  • With 4 inputs for temperature: PT100 and PT1000
  • 24VDC power supply
  • 16-bit resolution
  • Right-hand module

PLC DVP-06PT-SDVP-06PT-S:

  • With 6 inputs for temperature: PT100 and PT1000
  • 24VDC power supply
  • 16-bit resolution
  • Right-hand module

Communication modules

 

Communication modules

PLC DVP-COPM-SLDVP-COPM-SL:

  • CANOpen Master/Slave communication module
  • Communication modules
  • Left-hand module

PLC DVP-DNET-SLDVP-DNET-SL:

  • DeviceNet Master/Slave communication module
  • 24VDC power supply
  • Left-hand module

PLC DVP-DT01-SDVP-DT01-S:

  • DeviceNet Slave communication module
  • 24VDC power supply
  • Right-hand module

PLC DVP-EN01-SLDVP-EN01-SL:

  • Ethernet Master/Slave communication module
  • 24VDC power supply
  • Modbus TCP support
  • Option to view data from an Android system phone
  • Left-hand module

PLC DVP-PF01-SDVP-PF01-S:

  • Profibus Slave Communication Module
  • Baud rate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M [bps]
  • Maximum cable length: 1200 m (for max. speed 93.75 kbps)
  • Right-hand module

PLC DVP-PF02-SLDVP-PF02-SL:

  • Profibus Slave Communication Module
  • Baud rate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M [bps]
  • Maximum cable length: 1200 m (for max. speed 93.75 kbps)
  • Left-hand module

PLC DVP-SCM12-SLDVP-SCM12-SL:

  • Dual port RS485/RS422 communication module
  • Modbus ASCII/RTU communication protocols
  • Left-hand module

Software

Contact

Sales

Andrzej Gajtkowski

Module Sales Division Manager

+48 797 991 410

+48 56 654 49 06

andrzej.gajtkowski@apator.com

Technical

Marcin Iwiński

Control System Solution Division Manager

+48 506 009 277

+48 56 654 49 23

marcin.iwinski@apator.com

This site uses cookies. By using this website you agree to the use of cookies in accordance with current browser settings. Using our website without changing the settings for cookies is that they will be stored in memory. More information can be found in our Privacy Policy.
You can change the settings for cookies.

zamknięcie cookie's